INSTALLATION
PROPER INSTALLATION IS IMPORTANT. IF YOU NEED ASSISTANCE, CONSULT A CONTRACTOR, ELECTRICIAN
OR TELEVISION ANTENNA INSTALLER (CHECK WITH YOUR LOCAL BUILDING SUPPLY, OR HARDWARE STORE
FOR REFERRALS). TO PROMOTE CONFIDENCE, PERFORM A TRIAL WIRING BEFORE INSTALLATION.
Form a drip loop with the wire at least eight inches
below the exit from the sensor and at least eight inches
below the point of entry into the building. Anchor any
exposed wire with insulated cable clips. Run the wire
through the building to the location where the indicator
will be located. Caulk any holes when done.
Feed the AC adaptor's cord and the sensor wire to the indicator.
Connect the the two wires of the AC adaptor cord to the back of the
indicator with the supplied brass nuts. The polarity does not matter.
Connect the two wires from the temperature sensor to #1 and #2
screw terminals (reading #1 through #5, left to rignt). The polarity
does not matter. Do not plug the AC adapter in until all of the
connections have been made and checked.
Mount the temperature sensor assembly with the two
large wood screws. Select a location that is protected
from direct sunlight and sheltered. (A north exposure, six
feet above the ground will give the best results.)
1
2
3
4
DRIP
LOOP
WOOD
SCREWS
CAULK
CABLE
CLIP
8"
MIN
TO
TEMPERATURE
SENSOR
AC
ADAPTOR
Mount the brass read-out directly over the cable
feed-thru-hole to avoid crimping the wire under the lip.
We recommend mounting the read-out on one of our
pre-drilled and centered panels. Plug the power supply
into a 110 VAC power outlet.
CABLE-HOLE
WAL
L
SCREW
SCREW
PANEL
Page 1
30 Barnet Boulevard
New Bedford, MA 02745
(508) 995-2200
CRITERION
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - CRITERION

INSTALLATIONPROPER INSTALLATION IS IMPORTANT. IF YOU NEED ASSISTANCE, CONSULT A CONTRACTOR, ELECTRICIAN OR TELEVISION ANTENNA INSTALLER (CHECK WITH

Page 2

OPERATIONTROUBLE SHOOTING The trend register needle can be set by turning the center knob on the indicator dial. Unplug the AC adaptor and remove th

Page 3

2 OR 3 SENSOR OPTIONSCRITERIONAs a factory installed option, the Criterion has the ability to be built as a two sensor instrumentor three sensor instr

Page 4 - Recommended Prevention:

30 SAMUEL BARNET BOULEVARD NEW BEDFORD, MASSACHUSETTS 02745 U.S.A.TEL. 508.995.2200 WWW.MAXIMUM-INC.COM FAX 800.989.2580Page 4RW E A T H E R